500 Series Standard Options:

Optional Main Beam Lengths (B-XXX):
Main Beams may be ordered in any length from 26" to 104" between Trunnion Interface Mounts. Above 104" requires special beams. Below 26" can be dangerous due to tip over. "XXX" = length in inches between Trunnion Interface Mounts. (1" increments)

While the two End Frames can be adjusted toward each other to accommodate smaller length parts, excessively long beams with a small part will leave the Main Beams extending from each End Frame enough to be inconvenient. It therefore is desirable to order this Main Beam close to the size of the actual part-to-be-handled.

Optional Telescopic Main Beams (TB):
Telescopic Main Beams adjust from 66" to 104" between Trunnion Interface Mounts. They will do this without extending beyond the End frames. They can be adjusted down to 26" between Interface mounts by letting them extend beyond the End frames.

Optional Trunnion Interface/Mount/Clamp:
  1. Angle Interface (SA10) - The Angle Interface offers the most adaptability for customers. Either of the 2" perpendicular surfaces of the angle may be bolted or clamped to. The standard length is 10 inches with no bolt holes. The standard finish is clear zinc plate.

    SA10
    Enlarge Image

  2. Mounting Plate Interface (1018) - The part-to-be-handled can be easily bolted to this flange type interface. The standard size is 2" by 12.5" with a slotted-hole bolt pattern centered on the plate. The four holes will accept up to ¼" diameter bolts. The standard finish is clear zinc plate.

    1018
    Enlarge Image

  3. Board Clamp Interface (1023) - The Board Clamp Interface is a 10" long 2" x 2" angle with two screws clamps. It is very convenient for harness boards and similar shaped loads.

    1023
    Enlarge Image

Optional Index Plate (IND15):
Indexed @ 15° increments to prevent trunnion rotation with a lock pin. An Index plate can be supplied with either of the mounting interfaces, shown below or the SA10 angle interface.

IND15
Enlarge Image

IND15
Enlarge Image

Optional Casters:
  1. Standard Series 4 swivel caster (blank) - available only on the HD510 & HD525
  2. Optional Series 4 heavy duty Impak swivel caster (C1) - available only on the HD510 and HD525
  3. Standard Series 4 Caster with conductive wheel and Tech-Lock brake (C2). Optional on the HD510 and HD525 (not shown).
  4. Standard Series 2 swivel caster (C5SPX) - available only on the HD510-HYD
  5. Optional Series 2 caster with Total Lock brake (C5TL) - available only on the HD510-HYD
  6. Optional Series 2 caster with conductive wheel (C5EX) - Available only on the HD510-HYD

Optional Casters
Enlarge Image
Optional Gearbox:
The larger 715 size gearbox, which is standard on the HD510 & HD525, is also available on the HD510-HYD in place of the smaller 713 size gearbox.

Optional Fixture Finishes for use in Clean Room (C):
The fixture is supplied with most surfaces electroless nickel plated, the gearbox case is painted with white epoxy and miscellaneous hardware is made of stainless steel.

Optional Ground Lug and Drag Chain (E):
For use in electrostatically protected areas (EPA's). Proper electrostatic discharge (ESD) grounding of the fixture must be part of the overall EPA design (See Technical section discussion on ESD.

Special Options:
If a standard holding fixture does not meet your requirements, contact FLOTRON about custom modifications. Often, minor modifications to a standard unit are all you will need and can be done cost effectively.

For 500 Series - Creating a Model Number, click here.*

*Note: viewing these documents require Adobe's Acrobat Reader.

For clarification of terms or phrases, please see the Holding Fixtures Definitions page. All data presented is based on no modifications to the product.

As Flotron is constantly improving products and methods of manufacturing, we reserve the right to modify and/or change design or specifications without notice. Please contact Flotron for verification of critical dimensions and specifications.


Back to 500 Series Product Line


Angle Interface
Mounting Plate Interface
Board Clamp Interface
Optional Index Plate
Optional Casters
Optional Gearbox
Holding Fixture Definitions

SA10 Angle Interface
1018 Mounting Plate Interface
1023 Board Clamp Interface
IND15 Optional Index Plate with 1023 Board Clamp
IND15 Optional Index Plate with 1018 Mounting Plate
Optional Casters

500 SERIES Creating A Model Number ( 13.2KB )



About Flotron | Holding Fixtures | Extractors | Product FAQs
Tech Section | Contact Flotron
Site Map | Help | Terms and Conditions

Flotron, Inc.
2485 Coral Street
Vista, CA 92081 USA
(ph.) 760.727.2700  (fax) 760.727.3957



Site Map Help Site Map Help